Goodman outdoor air conditioning condenser installed on a gray equipment pad beside a stucco home.
Completed outdoor Goodman air conditioner installation.

The problem

What we found.

The homeowner needed an HVAC system upgrade to support dependable heating and cooling throughout the home.

The solution

What our team did.

Installed the outdoor Goodman condenser on an equipment pad and installed the furnace and evaporator coil in the attic. Connected refrigerant piping, electrical wiring, ductwork, venting, and condensate drainage. The installation photos document control wiring work and refrigerant evacuation, with the digital gauge displaying 195 microns.

Project photos

See the work.

Photos from this Brentwood project completed by In Demand Plumbing, Heating & Air.

Goodman outdoor air conditioning condenser installed on a gray equipment pad beside a stucco home.
Completed outdoor Goodman air conditioner installation.
Front view of the installed air conditioning condenser with a metal securing bracket on the equipment pad.
Outdoor condenser secured to its equipment pad.
Fieldpiece digital micron gauge displaying 195 microns during refrigerant system evacuation.
Refrigerant evacuation documented with a 195-micron reading.
Horizontal attic furnace connected to a foil-sealed metal duct transition and insulated ductwork.
Attic furnace installation connected to the home’s duct system.
HVAC technician connecting control wiring inside an open attic furnace cabinet.
Connecting furnace control wiring during installation.
Attic evaporator coil connected to a horizontal furnace, with insulated refrigerant piping, white condensate drains, an overflow safety switch, and a metal drain pan.
Completed attic coil installation with condensate drainage and overflow protection.